High Utilization Precision Air Handling Units For Server Rooms Equipment

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

High Utilization Precision Air Handling Units For Server Rooms Equipment

Brand Name : Coolent

Model Number : T56,T61,T70,T80,T90

Certification : ISO/CE

Place of Origin : China

MOQ : 1

Price : to be Negotiated

Payment Terms : T/T

Supply Ability : 1000/Month

Delivery Time : 4W

Packaging Details : WOODEN

Cooling capacity : 50-70KW

Mounting : On Floor Standing

Condition : Brand New

Type : Precision air conditioning unit( air cooled/water cooled )

Voltage : 380/400 VAC,230 VAC,220V

Warranty : 1 Year(12 month )

Name : PAC cooling unit

Refrigerant : R22(R407C/R410A)

Application : Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity

Color : Black/Grey

Power : 3N-380V-50Hz,220v/50hz/60hz

Contact Now

High Utilization Precision Air Handling Units For Server Rooms Equipment

Product Introduction

Coolnet precision air conditioners can precisely control the new energy and performance standards of data centers, server rooms and communication networks, as well as the temperature and humidity of computer rooms with low PUE target requirements, for high reliability, better humidity and temperature settings, and part load efficiency. Ensure the smooth operation of the equipment in the computer room, ensure the service life of the equipment, and reduce the company's maintenance costs.

Benefits

High Utilization Precision Air Handling Units For Server Rooms Equipment

High Utilization Precision Air Handling Units For Server Rooms Equipment

Applications

High Utilization Precision Air Handling Units For Server Rooms Equipment

  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Features

Precise and reliable
Careful design, strict laboratory testing and comprehensive quality control ensure the unit has excellent reliability;The unit uses parts of world-renowned brands to ensure the high reliability and service life of the whole machine.
Energy saving and high efficiency

Energy saving and high efficiency
Save a lot of energy consumption in a reasonable and feasible way, and make full use of natural resources;
The unit uses a high-efficiency fan and a fully enclosed compressor system to reduce operating costs and always pay attention to energy efficiency.

Multiple air supply
The air supply method of the air-conditioned room depends on the source and distribution characteristics of the heat in the room. According to the dense arrangement of equipment in the computer room, the number of cables and bridges, and the wiring method, the air supply method of the air conditioner is divided into lower delivery, upper return, top feed back, top feed side back, side feed side back.

Static pressure box air supply
The air conditioner in the computer room usually does not use pipes, but uses the space at the lower part of the raised floor or the upper part of the ceiling as the return air of the static pressure box. static pressure is equal.

High Utilization Precision Air Handling Units For Server Rooms Equipment

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

High Utilization Precision Air Handling Units For Server Rooms Equipment

Factory Details

High Utilization Precision Air Handling Units For Server Rooms Equipment

Packing & Delivery

High Utilization Precision Air Handling Units For Server Rooms Equipment

Case

High Utilization Precision Air Handling Units For Server Rooms Equipment


Product Tags:

Precision Air Handling Units Floor Standing

      

High Utilization Precision Ahu

      

Server Room Equipment Precision Ahu

      