Brand Name : Coolnet
Model Number : M22
Certification : CE/ISO9001
Place of Origin : China
MOQ : 1
Price : $1000.00-5000.00/set
Payment Terms : T/T
Supply Ability : 1000-5000/set/month
Delivery Time : 4W
Packaging Details : WOODED
Cooling Capcity : 20-120KW
Color : Black/Grey white/other custom colors
Mounting : Floor Standing
operating voltage : 380/400 VAC,230 VAC,220V
Application : Data Center, IT room , Computer room, Servers rooms, Laboratories, Telecommunication
Power : 3N-380V-50Hz,220v/50hz/60hz
Airflow : Down Flow
Product : precision air conditioning unit/ data center cooling unit /computer room unit /close control unit
Compressor : Danfoss/Emerson Scroll Compressor
Fan : EC Fan
High Air Volume Water-Cooled Type Data Center Cooling System Of Close Control Unit
Products Introduction Close Control Unit (CCU) also Know as Precision Air Conditioner or Close Control Air Conditioner or Computer Room Air Conditioner (CRAC) or server room air conditioner use for precise control of Temperature and Humidity required for critical application like Server room, Datacenter, Laboratories, Telecommunication room etc. Precision Cooling Unit: With high AEER system design and team work function, CyberMateTM meets the cooling demand and reduce the PUE of the data center.
Benefits | ![]() |
Air Supply Method
Features
![]() | 1.Cooling capacity: 7.5KW-120KW |
Applications
| ![]() |
Advantages
![]() | ·Precise and reliable Careful design, strict laboratory testing and comprehensive quality control ensure the unit has excellent reliability;The unit uses parts of world-renowned brands to ensure the high reliability and service life of the whole machine.
·Energy saving and high efficiency Save a lot of energy consumption in a reasonable and feasible way, and make full use of natural resources; The unit uses a high-efficiency fan and a fully enclosed compressor system to reduce operating costs and always payattention to energy efficiency.
·Health and Environmental Protection Effective ventilation, providing fresh and clean natural air,reducing indoor polutants and improving indoor air quality. The unit uses environmentally friendly vefrigerant R4O7C/R4104, which is most conducive to ecological environment pro-tection, and pay attention to environmental sustainable development.
·Intelligent control Fighly intelligent microprocessor control system, veliable operation, convenient use and maintenance, strong anti-inter-ference abillity, can keep the unit in the best operating state; With various protection functions, it can also realze unit joint control, and can be connected to a common open protocolto easily realize building control (support RS485,RS232, ModBUS, LonWORKS, BacNET and lP protocol SNMP) |
Technical Parameters
Model: CYA | T26D/U | T31D/U | T35D/U | T41D/U | T45D/U | T50D/U | T55D/U | T61D/U | T70D/U | T76D/U | T85D/U | T90D/U | T100D/U | |
Power Supply | 380V 3Ph-50HZ | |||||||||||||
Air Discharge | Upflow/Downflow | |||||||||||||
Cooling Capacity :24℃/50%RH | ||||||||||||||
Total Capacity (1) | KW | 26.9 | 31.9 | 35.9 | 41.9 | 45.3 | 50.5 | 55.4 | 61.4 | 70.5 | 76.2 | 85.5 | 90.8 | 102 |
Sensible | KW | 24.8 | 29.5 | 33.1 | 38.8 | 42.5 | 47.8 | 51.6 | 57.5 | 65.2 | 71.2 | 79.5 | 84.5 | 95.7 |
AEER | W/W | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.7 | 3.7 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
Air Flow | m3/h | 8000 | 9500 | 10000 | 11500 | 13000 | 15500 | 16000 | 17500 | 18500 | 20500 | 22500 | 23500 | 24200 |
Compressor Hermetic scroll | ||||||||||||||
Refrigerant | R407C | |||||||||||||
Compressor quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Fan Section Centrifugal fan (Optional EC) | ||||||||||||||
Fan quantity | PC | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 |
Rated current | A | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 5 | 5.2 | 5.2 | 6.5 | 16.5 | 16.5 | 16.5 |
Rated power | W | 1600 | 1600 | 1800 | 1800 | 2000 | 2000 | 3000 | 3300 | 3900 | 3900 | 5400 | 6300 | 6300 |
Total heating capacity | KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 |
Material | PTC | |||||||||||||
Humidifier Section Electrode type | ||||||||||||||
Capacity | Kg/h | 5 | 5 | 5 | 5 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
Rated Current | A | 6 | 6 | 6 | 6 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 |
Condenser Model | 2*58 | 2*58 | 2*58 | 2*58 | 2*80 | 2*80 | 2*100 | 2*100 | 2*120 | 2*150 | 2*150 | 2*165 | 2*180 |
Certificates
Factory Details
Packing & Delivery
Case
![]() |
High Air Volume Water-Cooled Type Data Center Cooling System Of Close Control Unit Images |