Branch Offices Micro Data Centers With PAC Units Edge Computing

  • 1
  • 2
  • 3

Brand Name : COOLNET

Model Number : EC20, ERx

Certification : CE ISO

Place of Origin : CHINA

MOQ : 1PCS

Price : USD000-10000/PCS

Payment Terms : L/C, T/T

Supply Ability : 200 SETS PER MONTH

Delivery Time : 20-35 days

Packaging Details : Standard export package

Application : Network closets or telecom sites , Edge Computing

Voltage : 380v/220v,110-220v/50-60Hz,220V/50Hz

Cabinet Quatities : Single cabinet/Multiple cabinets

Operating voltage : 380/400 VAC,230 VAC,220V(380V)/50HZ,AC 220V

UPS type : Online ,Rack mounted type

Cabinet type : 26U 42U 65U

Contact Now

Branch Offices Available Micro Data Center With Rack PAC Units For Edge Computing

Product Intoduction

A micro data center is a small version of traditional equipment, shaped like a large metal container. Compared to traditional data centers, these scaled-down versions are designed for different types of workloads and can solve specific problems that traditional data centers cannot. A micro data center is the integration of traditional data center infrastructure (including in-rack, cooling, UPS, PDU, monitoring, and other subsystems) in a single 19-inch rack or multiple-racks. It is portable, quick to deploy, efficient and cost-effective, suitable for branch offices and dense urban centers, especially for edge computing and edge analytics. Branch Offices Micro Data Centers With PAC Units Edge Computing

Branch Offices Micro Data Centers With PAC Units Edge Computing

Advantages

Branch Offices Micro Data Centers With PAC Units Edge Computing Reduce costs. With micro data centers, businesses don't have to concentrate upfront capital expenditures on traditional server hardware. Compared to enterprise data centers, the operating expenses of micro data centers are much lower. Additionally, the distance between client and server computers reduces the higher power costs associated with transferring computations to centralized data centers.

Local computing. Micro data centers reduce the geographic distance between client and server computers. The reduced proximity greatly reduces latency.

Small footprint. Compared to large data centers, micro data centers have much lower carbon emissions.

Greater elasticity. Traditional data centers are often at risk of service disruption if priority lines are damaged. Even with network redundancy in place, traditional data centers will struggle to compete with the options of micro data centers in the event of a failure. Micro data centers may have dozens of failover strategies.

A flexible infrastructure approach. Depending on demand, businesses can choose to scale their data needs up or down. The scalability of a micro data center makes it easy to align with enterprise goals.

Application

  • Edge Computing
  • Smart facilities deploying IoT devices and/or running Artificial Intelligence (AI), Augmented Reality (AR), Virtual Reality (VR), Automation, etc.
  • As a computing node in remote and branch offices
  • As a floor distributor
Branch Offices Micro Data Centers With PAC Units Edge Computing

Technical Parameter

Model EC08 EC12 EC20 ERx
Power 3KVA 3-6KVA 6-30KVA
Number of cabinets 0.8m high cabinet, available space 8U 1.2m high cabinet, available space 16U Standard 42U cabinet, free space 30U 2-10 standard 42U glass door cabinets
Enclosed cabinet Glass door, IP5X, full cold and hot channel sealing
Power supply 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection
Refrigeration Unique air duct design, without air conditioner and outdoor unit Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation;
Monitor 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring

Certification

Branch Offices Micro Data Centers With PAC Units Edge Computing

Factory View

Branch Offices Micro Data Centers With PAC Units Edge Computing


Product Tags:

PAC Units Micro Data Centers

      

Branch Offices Micro Data Centers

      