Two Cabinets Rack Data Center With Rack Mounted Precision Air Conditioners Installed
Product Introduction
The Coolnet's Rack Data Center is the product integrated the functions of a series of equipment such as power distribution, air conditioning, environmental control, and monitoring. It has powerful functions, small footprint, and more convenient management and construction. As a result, it can be widely used in many places, such as small and medium computer rooms and business, edge computing, smart city, etc.. | ![]() |
Feature
![]() |
Wisdom
Efficient
Simply
Edge Brain Infrastructure Monitoring
|
Technical Parameter
Model | EC08 | EC12 | EC20 | ERx |
Power | 3KVA | 3-6KVA | 6-30KVA | |
Number of cabinets | 0.8m high cabinet, available space 8U | 1.2m high cabinet, available space 16U | Standard 42U cabinet, free space 30U | 2-10 standard 42U glass door cabinets |
Enclosed cabinet | Glass door, IP5X, full cold and hot channel sealing | |||
Power supply | 220VAC, 3KVA UPS, power backup customized as required, Class C lightning protection | 220VAC, 3-6KVA UPS, customized standby power, C-level lightning protection | 220V/380VAC, 6-30KVA UPS, power backup customized as required, Class C lightning protection | |
Refrigeration | Unique air duct design, without air conditioner and outdoor unit | Refrigerating capacity 3.5-6.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | Refrigerating capacity 3.5-10.5KW optional, variable frequency EC fan; Quick coupling; Low load anti condensation; | |
Monitor | 1U rack type monitoring host, monitoring temperature and humidity, door magnet, smoke sensor, electricity, etc., without display | 1U rack type monitoring host/10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring | 10 inch touch screen monitoring host (0U), temperature and humidity, door magnet, smoke sensor, electricity, refrigeration monitoring |